maxit Solarfarbe

Extbase Variable Dump
array(20 items)
   web_produktbild => array(1 item)
      0 => array(5 items)
         id => 'pixelboxx_produktbild' (21 chars)
         name => 'Pixelboxx_Produktbild' (21 chars)
         value => array(4 items)
            urls => array(1 item)
               0 => '111611_maxit_Solarfarbe.jpg' (27 chars)
            description => 'MAM_Pixelboxx:pboxx-pixelboxx-13526' (35 chars)
            contentType => '' (0 chars)
            url => '111611_maxit_Solarfarbe.jpg' (27 chars)
         type => '&[de.myview.objectmodel.util.Hyperlink]' (39 chars)
         position => '05-001' (6 chars)
   web_produktbezeichnung => array(1 item)
      0 => array(5 items)
         id => 'produktbezeichnungProduktname' (29 chars)
         name => 'Produktbezeichnung / Produktname' (32 chars)
         value => 'maxit Solarfarbe' (16 chars)
         type => '&[java.lang.String]' (19 chars)
         position => '03-005' (6 chars)
   web_produktkurzbeschreibung => array(1 item)
      0 => array(5 items)
         id => 'produktkurzbeschreibung' (23 chars)
         name => 'Produktkurzbeschreibung' (23 chars)
         value => 'maxit Solarfarbe ist eine lösungsmittelfreie Fassadenfarbe auf Silikonharzb
            asis mit mineralischer Grundstruktur und einem hohen Anteil an microfeinen H
            ohlglaskugeln. <br/><br/> Der hohe Anteil an Microhohlglaskugeln bewirkt ein
            en Isoliereffekt der Farbe, der zu einer deutlichen Verlangsamung der Wärme
            durchleitung führt. Damit wird der Taupunkt an der Fassade positiv beeinflu
            sst, die Wand bleibt länger trocken. <br/><br/> maxit Solarfarbe ist wasser
            abweisend eingestellt (niedrige kapillare Wasseraufnahme W3), hat aber durch
             ihre spezielle Rezeptur eine microporöse hydrophile Oberfläche, die anhaf
            tende Feuchtigkeit sehr schnell von der Oberfläche ableitet. <br/><br/> Du
            rch die Kombination der beiden beschriebenen physikalischen Effekte wird mit
             maxit Solarfarbe ein lang anhaltender Schutz der Fassade gegen Algen- und P
            ilzbefall erreicht, der sich im Laufe der Jahre, im Gegensatz zu herkömmlic
            her fungizider algizider Ausrüstung, auch nicht abbaut. <br/><br/> Diese au
            sgezeichneten bauphysikalischen Eigenschaften machen maxit Solarfarbe zu ein
            em äußerst leistungsfähigen Wetterschutz an der Fassade. <br/><br/> Ein
            zweimaliger Anstrich mit maxit Solarfarbe ist unbedingt erforderlich um die
            beschriebenen Produktvorteile zu erreichen. Weiß oder farbig nach maxit kre
            ativ Farbtonkarte.
' (1311 chars) type => '&[java.lang.String]' (19 chars) position => '03-010' (6 chars)
web_produkttexte => array(21 items) 0 => array(5 items) id => 'produkteigenschaften' (20 chars) name => 'Produkteigenschaften' (20 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '03-015' (6 chars) 1 => array(5 items) id => 'anwendungsbereich' (17 chars) name => 'Anwendungsbereich' (17 chars) value => 'maxit Solarfarbe ist eine lösungsmittelfreie Fassadenfarbe mit mineralische
            r Grundstruktur, einsetzbar auf maxit Solarputz oder maxit Solarfassadenspac
            htel bzw. maxit silco A 9030, maxit spectra A 9040, maxit sil A 9020, allen
            Putzarten und mineralischen Untergründen.<br/>
' (275 chars) type => '&[java.lang.String]' (19 chars) position => '03-020' (6 chars)
2 => array(5 items) id => 'produktvorteile' (15 chars) name => 'Produktvorteile' (15 chars) value => '<ul><li>langlebiger, ökologischer Schutz der Bausubstanz</li><li>optimaler
            Schutz gegen Algen</li><li>langanhaltende Farbbrillanz</li><li>wärmeregulie
            rend</li><li>spannungsarme, flexible Fassadenbeschichtung</li><li>feuchtereg
            ulierend durch microporöse Struktur</li><li>geringe Verschmutzungsneigung</
            li></ul>
' (312 chars) type => '&[java.lang.String]' (19 chars) position => '03-025' (6 chars)
3 => array(5 items) id => 'baustellenvoraussetzungen' (25 chars) name => 'Baustellenvoraussetzungen' (25 chars) value => 'Der Untergrund muss trocken, fest, frei von Staub und losen Teilen bzw. Tren
            nmitteln (z.B. Schalöl) sein. Die Objekt- und Umgebungstemperatur darf nich
            t unter <br/>+ 5&deg;C und nicht über + 30&deg;C liegen. Die Trockenzeiten
            liegen bei Normalbedingungen (+ 20&deg;C / 65 % Luftfeuchte) bei ca. 12 Stun
            den, tiefere Temperaturen und höhere Luftfeuchte verlängern diese Zeit.
' (377 chars) type => '&[java.lang.String]' (19 chars) position => '03-050' (6 chars)
4 => array(5 items) id => 'einbausituation' (15 chars) name => 'Einbausituation' (15 chars) value => NULL type => 'list' (4 chars) position => '03-050' (6 chars) 5 => array(5 items) id => 'untergrund' (10 chars) name => 'Untergrund' (10 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '03-051' (6 chars) 6 => array(5 items) id => 'untergrundvorbereitung' (22 chars) name => 'Untergrundvorbereitung' (22 chars) value => '<span>Je nach Untergrund ist ein Voranstrich mit maxit prim 1070 Tiefgrund,
             maxit Solarfarbgrund oder maxit prim 1110 Hydrogrund erforderlich. <br/>Sc
            hmutzempfindliche Bauteile abdecken bzw. wasserfest abkleben. <
            /span>
' (234 chars) type => '&[java.lang.String]' (19 chars) position => '03-055' (6 chars)
7 => array(5 items) id => 'verarbeitung' (12 chars) name => 'Verarbeitung' (12 chars) value => 'maxit Solarfarbe ist gebrauchsfertig. Eine Verdünnung kann bei Grund- und Z
            wischenanstrichen ca. 5 - 10 %, bei Schlussanstrichen bis ca. 2 - 5 % mit sa
            uberem Wasser erfolgen. Vor der Verarbeitung ist die Solarfarbe gut aufzurü
            hren. Nicht bei direkter Sonneneinstrahlung, Regen oder hoher Luftfeuchtigke
            it verarbeiten. Dieses Produkt stets sicher verwenden. Produktinformationen
            vor Gebrauch beachten.
' (403 chars) type => '&[java.lang.String]' (19 chars) position => '03-060' (6 chars)
8 => array(5 items) id => 'anwendungsbeispiel' (18 chars) name => 'Anwendungsbeispiel' (18 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '03-061' (6 chars) 9 => array(5 items) id => 'materialverbrauch' (17 chars) name => 'Materialverbrauch' (17 chars) value => 'Je nach Art und Saugverhalten des Untergrundes ca. <br/>0,2 - 0,4 l/m² bei
            einmaligen Anstrich. Achtung: Raue Oberflächen können den Verbrauch erhöh
            en. Exakte Verbrauchsmengen sind durch Anlegen von Probeflächen zu ermittel
            n.
' (230 chars) type => '&[java.lang.String]' (19 chars) position => '03-062' (6 chars)
10 => array(5 items) id => 'nachbehandlungBeschichtung' (26 chars) name => 'Nachbehandlung / Beschichtung' (29 chars) value => '<b>Nachbehandlung:</b><br/> Frische Farbe vor zu schneller Austrocknung durc
            h Sonneneinstrahlung und/ oder Wind schützen. <br/><br/><b>Beschichtung:</
            b><br/> Eine 100%ige Farbtongleichheit zwischen Oberfläche und Farbe oder a
            uch den Farbtonfächern kann aufgrund der unterschiedlichen Pigmentierung ni
            cht gewährleistet werden. Farbtonunterschiede sind auch bei gleichem Farbto
            n nicht immer auszuschließen. maxit Solarfarbe kann mit Silikat-Dispersion-
            , Siliconharz- und Dispersionsfarben überarbeitet werden. <br/><br/><b>Weit
            erverarbeitung:</b><br/> Bei intensiven Farbtönen und ungleichen Farben z.B
            . weißer Putz, farbigen Anstrich und zum Erreichen eines guten Witterungssc
            hutzes, ist generell ein zweimaliger Anstrich auszuführen. Die Standzeiten
            des maxit Oberputzes bis zum Farbauftrag sind dem Hinweisblatt „Minimale S
            tandzeiten vor dem Farbauftrag“ unter <br/>www.maxit.de zu entnehmen.
' (907 chars) type => '&[java.lang.String]' (19 chars) position => '03-065' (6 chars)
11 => array(5 items) id => 'gerätereinigung' (16 chars) name => 'Gerätereinigung' (16 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '03-066' (6 chars) 12 => array(5 items) id => 'allgemeineHinweise' (18 chars) name => 'Allgemeine Hinweise' (19 chars) value => 'In Zweifelsfällen bezüglich Verarbeitung oder Objektbesonderheiten Beratun
            g anfordern. Keine Fremdstoffe beimischen. <br/> Haut und Augen schützen,
             bei Berührung gründlich mit Wasser spülen, bei Augenkontakt unverzüglic
            h Arzt aufsuchen. <br/> Sicherheitsdatenblatt beachten (aktuelles Sicherheit
            sdatenblatt unter www.maxit.de). <br/> In abgebundenem Zustand physiologisch
             und ökologisch unbedenklich.
' (412 chars) type => '&[java.lang.String]' (19 chars) position => '03-070' (6 chars)
13 => array(5 items) id => 'besondereHinweise' (17 chars) name => 'Besondere Hinweise' (18 chars) value => '<span><span><span><b>Zu beachten:</b> Prüfung des Materials vor Verarbeitu
            ng, ob es dem bestellten Farbton entspricht. Es kann zu geringen Farbtonabw
            eichungen vorhergegangener Lieferungen kommen. Auf zusammenhängenden Fläc
            hen nur Material einer Charge verwenden. Vor der Verarbeitung sind untersch
            iedliche Chargen zu mischen. Abzeichnungen von Ausbesserungen in der Fläch
            e hängen von vielen Faktoren ab und sind daher unvermeidbar (BFS-Merkblatt
             25).<br/><br/>Bei dichten, kühlen Untergründen oder bei witterungsbeding
            ter Trocknungsverzögerung, können durch Feuchtebelastung (Regen, Tau, Neb
            el) Hilfsstoffe an der Oberfläche der Beschichtung gelblich/transparente,
             leicht glänzende und klebrige Ablaufspuren entstehen. Diese Hilfsstoffe s
            ind wasserlöslich und werden&nbsp; mit ausreichend Wasser, z.B. nach mehrm
            aligen stärkeren Regenfällen selbstständig entfernt. Die Qualität der g
            etrockneten Beschichtung wird dadurch nicht nachteilig beeinflusst. Bei Aus
            führung der Beschichtung unter geeigneten klimatischen Bedingungen treten
            diese Ablaufspuren nicht auf. </span></span></span>
' (1115 chars) type => '&[java.lang.String]' (19 chars) position => '03-075' (6 chars)
14 => array(5 items) id => 'qualität' (9 chars) name => 'Qualität' (9 chars) value => 'Der Einsatz bewährter und fortlaufend kontrollierter Rohstoffe garantiert e
            ine gleichbleibend gute Qualität. Modernste Fertigungsanlagen sorgen für k
            onstante Produkteigenschaften. In den werkseigenen Baustofflaboren erfolgt e
            ine konstante Qualitätsüberwachung der Produkte.
' (279 chars) type => '&[java.lang.String]' (19 chars) position => '03-076' (6 chars)
15 => array(5 items) id => 'lagerung' (8 chars) name => 'Lagerung' (8 chars) value => 'Vor Frost schützen. In original verschlossenen Gebinden mindestens 12 Monat
            e lagerfähig.
' (90 chars) type => '&[java.lang.String]' (19 chars) position => '03-080' (6 chars)
16 => array(5 items) id => 'entsorgung' (10 chars) name => 'Entsorgung' (10 chars) value => 'Eimer sind komplett zu entleeren, Entsorgung gemäß den behördlichen Vorsc
            hriften.<br/><br/><br/><br/><br/><br/><br/><br/><br/>
' (129 chars) type => '&[java.lang.String]' (19 chars) position => '03-083' (6 chars)
17 => array(5 items) id => 'technischeDaten' (15 chars) name => 'Technische Daten' (16 chars) value => '<b>Airless Spritzdaten:<br/></b><table class="te"><tbody><tr class="te"><td
            class="te">Verdünnung&nbsp;&nbsp; <br/></td><td class="te">5 % mit Wasser&n
            bsp; <br/></td></tr><tr class="te"><td class="te">Spritzdruck</td> <td class
            ="te"><span>≤ 80</span> bar* / **<br/></td></tr><tr class="te"><td class="
            te">Düsengröße</td> <td class="te">0,023<br/></td></tr><tr class="te"><td
             class="te">Maschenweite Sieb&nbsp;&nbsp; <br/></td><td class="te">60 mesh<b
            r/></td></tr><tr class="te"><td class="te">Schlauchlänge</td> <td class="te
            ">mind. 15 m x 1/4"<br/></td></tr></tbody></table> <br/><br/><sup>bar* Druc
            keinstellungen sind den Gegebenheiten anzupassen, sie sind von Lieferkonsist
            enz und Umgebungstemperatur stark beeinflusst.<br/>** erhöhter Druck führt
             zu Materialschäden</sup><sup><span><span><span/></span></span><br/></sup><
            b><br/>Sicherheitshinweis:</b> Bei allen Spritzapplikationen sind die Verarb
            eitungsrichtlinien der Produkte sowie der verwendeten Spritzgeräte zu beach
            ten. Bei Verarbeitung aller Materialien ist sicherzustellen, dass die Bauste
            lle entsprechend gut belüftet wird, ent-sprechende Arbeitsschutzmasken zu t
            ragen sind und die Geräte entsprechend gesichert sind (Ex-Schutz)<sup>.<spa
            n><span><span/></span></span></sup>
' (1251 chars) type => '&[java.lang.String]' (19 chars) position => '03-085' (6 chars)
18 => array(5 items) id => 'rechtlicheHinweise' (18 chars) name => 'Rechtliche Hinweise' (19 chars) value => 'Die genannten Werte und die zugesicherten Eigenschaften sind das Ergebnis in
            tensiver Entwicklungsarbeit und umfangreicher praktischer Erfahrungen. Sie b
            asieren auf den Ergebnissen sowohl der Eigen- wie auch der Fremdüberwachung
            . Unsere Empfehlungen zur Anwendung in Wort und Schrift sollen Hilfestellung
            en bei der Auswahl unserer Produkte geben, sie bekunden jedoch kein vertrag
            liches Rechtsverhältnis. Wir gehen davon aus, dass der Kunde als Fachbetrie
            b in eigener Verantwortung entsprechend der gültigen Vorschriften und den a
            nerkannten Regeln der Technik seine Arbeit ausführt. Die fachgerechte und d
            amit erfolgreiche Anwendung unserer Erzeugnisse unterliegt nicht unserer Kon
            trolle. Hinweise, wie z.B. die Aufzählung geeigneter Putzuntergründe, habe
            n nicht den Charakter einer zugesicherten Eigenschaft und entbinden den Kun
            den nicht von seiner Prüfungspflicht. Des Weiteren bitte auch die gültige
            n technischen Merkblätter des Bundesausschusses für Farbe und Sachwertschu
            tz (=BFS), 60327 Frankfurt, berücksichtigen. Mit dem Erscheinen dieses Merk
            blattes verlieren alle früheren Merkblätter ihre Gültigkeit.
' (1127 chars) type => '&[java.lang.String]' (19 chars) position => '03-090' (6 chars)
19 => array(5 items) id => 'logistik' (8 chars) name => 'Logistik' (8 chars) value => 'In Eimern á 5 / 15 Liter' (25 chars) type => '&[java.lang.String]' (19 chars) position => '03-999' (6 chars) 20 => array(5 items) id => 'siloUndMaschinentechnik' (23 chars) name => 'Silo- und Maschinentechnik' (26 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '03-999' (6 chars)
web_technische_daten => array(86 items) 0 => array(5 items) id => 'abmessung' (9 chars) name => 'Abmessung' (9 chars) value => NULL type => 'list' (4 chars) position => '04-015' (6 chars) 1 => array(5 items) id => 'abtönung' (9 chars) name => 'Abtönung' (9 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-016' (6 chars) 2 => array(5 items) id => 'anwendungInnen' (14 chars) name => 'Anwendung innen' (15 chars) value => FALSE type => '[java.lang.Boolean]' (19 chars) position => '04-017' (6 chars) 3 => array(5 items) id => 'anwendungAussen' (15 chars) name => 'Anwendung aussen' (16 chars) value => TRUE type => '[java.lang.Boolean]' (19 chars) position => '04-018' (6 chars) 4 => array(5 items) id => 'auftragsverfahren' (17 chars) name => 'Auftragsverfahren' (17 chars) value => NULL type => 'list' (4 chars) position => '04-020' (6 chars) 5 => array(5 items) id => 'baustoffklasse' (14 chars) name => 'Baustoffklasse' (14 chars) value => NULL type => 'list' (4 chars) position => '04-030' (6 chars) 6 => array(5 items) id => 'beständigkeitBlähton' (22 chars) name => 'Beständigkeit (Blähton)' (25 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-031' (6 chars) 7 => array(5 items) id => 'biegezugfestigkeit' (18 chars) name => 'Biegezugfestigkeit' (18 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-032' (6 chars) 8 => array(5 items) id => 'biegezugfestigkeitNach28TagenMin' (32 chars) name => 'Biegezugfestigkeit nach 28 Tagen, min.' (38 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-035' (6 chars) 9 => array(5 items) id => 'bindemittel' (11 chars) name => 'Bindemittel' (11 chars) value => NULL type => 'list' (4 chars) position => '04-040' (6 chars) 10 => array(5 items) id => 'brandverhalten' (14 chars) name => 'Brandverhalten' (14 chars) value => NULL type => 'list' (4 chars) position => '04-045' (6 chars) 11 => array(5 items) id => 'dauerhaftigkeit' (15 chars) name => 'Dauerhaftigkeit' (15 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-050' (6 chars) 12 => array(5 items) id => 'dauerhaftigkeitGegenüberFrostTausalz' (37 chars) name => 'Dauerhaftigkeit (gegenüber Frost-Tausalz)' (42 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-055' (6 chars) 13 => array(5 items) id => 'deckkraftklasse' (15 chars) name => 'Deckkraftklasse' (15 chars) value => ' Klasse 2 (DIN ISO 6404-3) ' (27 chars) type => '&[java.lang.String]' (19 chars) position => '04-058' (6 chars) 14 => array(5 items) id => 'dichte' (6 chars) name => 'Dichte' (6 chars) value => ' 1,0 <span>±</span> 0,1 g/cm³' (31 chars) type => '&[java.lang.String]' (19 chars) position => '04-060' (6 chars) 15 => array(5 items) id => 'din' (3 chars) name => 'DIN' (3 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-065' (6 chars) 16 => array(5 items) id => 'druckfestigkeit' (15 chars) name => 'Druckfestigkeit' (15 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-066' (6 chars) 17 => array(5 items) id => 'druckfestigkeitNach28Tagen' (26 chars) name => 'Druckfestigkeit nach 28 Tagen' (29 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-070' (6 chars) 18 => array(5 items) id => 'druckfestigkeitNach7Tagen' (25 chars) name => 'Druckfestigkeit nach 7 Tagen' (28 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-075' (6 chars) 19 => array(5 items) id => 'druckfestigkeitsklasse' (22 chars) name => 'Druckfestigkeitsklasse' (22 chars) value => NULL type => 'list' (4 chars) position => '04-080' (6 chars) 20 => array(5 items) id => 'eModul28' (8 chars) name => 'E-Modul' (7 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-085' (6 chars) 21 => array(5 items) id => 'empfohleneSchichtdicke35' (24 chars) name => 'Empfohlene Schichtdicke' (23 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-090' (6 chars) 22 => array(5 items) id => 'empfohlenerWassergehalt' (23 chars) name => 'Empfohlener Wassergehalt' (24 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-095' (6 chars) 23 => array(5 items) id => 'en' (2 chars) name => 'EN' (2 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-100' (6 chars) 24 => array(5 items) id => 'ergiebigkeit' (12 chars) name => 'Ergiebigkeit' (12 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-105' (6 chars) 25 => array(5 items) id => 'abbindezeit' (11 chars) name => 'Abbindezeit' (11 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-110' (6 chars) 26 => array(5 items) id => 'ergiebigkeit17' (14 chars) name => 'Ergiebigkeit' (12 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-110' (6 chars) 27 => array(5 items) id => 'ergiebigkeit15' (14 chars) name => 'Ergiebigkeit' (12 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-115' (6 chars) 28 => array(5 items) id => 'farbe' (5 chars) name => 'Farbe' (5 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-116' (6 chars) 29 => array(5 items) id => 'fasern' (6 chars) name => 'Fasern' (6 chars) value => NULL type => '[java.lang.Boolean]' (19 chars) position => '04-125' (6 chars) 30 => array(5 items) id => 'festmörtelPorosität' (21 chars) name => 'Festmörtel - Porosität' (24 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-130' (6 chars) 31 => array(5 items) id => 'festmörtelrohdichte' (20 chars) name => 'Festmörtelrohdichte' (20 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-131' (6 chars) 32 => array(5 items) id => 'festporen45' (11 chars) name => 'Festporen' (9 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-135' (6 chars) 33 => array(5 items) id => 'frischmörtelLuftporengehalt44' (30 chars) name => 'Frischmörtel - Luftporengehalt' (31 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-140' (6 chars) 34 => array(5 items) id => 'frischbetondichte' (17 chars) name => 'Frischbetondichte' (17 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-145' (6 chars) 35 => array(5 items) id => 'frostUndTausalzbeständigkeit' (29 chars) name => 'Frost- und Tausalzbeständigkeit' (32 chars) value => NULL type => '[java.lang.Boolean]' (19 chars) position => '04-150' (6 chars) 36 => array(5 items) id => 'frostbeständigkeit' (19 chars) name => 'Frostbeständigkeit' (19 chars) value => NULL type => '[java.lang.Boolean]' (19 chars) position => '04-155' (6 chars) 37 => array(5 items) id => 'gefahrenkennzeichnung' (21 chars) name => 'Gefahrenkennzeichnung' (21 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-160' (6 chars) 38 => array(5 items) id => 'glanzgradOberfläche' (20 chars) name => 'Glanzgrad/Oberfläche' (21 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-161' (6 chars) 39 => array(5 items) id => 'haftzugfestigkeitMin' (20 chars) name => 'Haftzugfestigkeit, min.' (23 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-165' (6 chars) 40 => array(5 items) id => 'kapWasseraufnahme' (17 chars) name => 'Kap. Wasseraufnahme' (19 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-166' (6 chars) 41 => array(5 items) id => 'kontrastverhältnis' (19 chars) name => 'Kontrastverhältnis' (19 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-167' (6 chars) 42 => array(5 items) id => 'körnung' (8 chars) name => 'Körnung' (8 chars) value => 'max. 100 µm' (12 chars) type => '&[java.lang.String]' (19 chars) position => '04-175' (6 chars) 43 => array(5 items) id => 'maximalerAuftrag' (16 chars) name => 'Maximaler Auftrag' (17 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-180' (6 chars) 44 => array(5 items) id => 'maximaleSchichtdicke' (20 chars) name => 'Maximale Schichtdicke' (21 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-181' (6 chars) 45 => array(5 items) id => 'minimaleSchichtdicke' (20 chars) name => 'Minimale Schichtdicke' (21 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-185' (6 chars) 46 => array(5 items) id => 'minimaleSchichtdicke20' (22 chars) name => 'Minimale Schichtdicke' (21 chars) value => NULL type => '[de.myview.util.Dimension]' (26 chars) position => '04-185' (6 chars) 47 => array(5 items) id => 'minimalerAuftrag43' (18 chars) name => 'Minimaler Auftrag' (17 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-190' (6 chars) 48 => array(5 items) id => 'minimalerAuftragInnen' (21 chars) name => 'Minimaler Auftrag - innen' (25 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-195' (6 chars) 49 => array(5 items) id => 'minimalerAuftragAußen' (22 chars) name => 'Minimaler Auftrag - außen' (26 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-200' (6 chars) 50 => array(5 items) id => 'mischungsverhältnis' (20 chars) name => 'Mischungsverhältnis' (20 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-205' (6 chars) 51 => array(5 items) id => 'mörtelgruppe' (13 chars) name => 'Mörtelgruppe' (13 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-206' (6 chars) 52 => array(5 items) id => 'nassabriebbeständigkeit' (24 chars) name => 'Nassabriebbeständigkeit' (24 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-207' (6 chars) 53 => array(5 items) id => 'oberflächenhärte' (18 chars) name => 'Oberflächenhärte' (18 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-208' (6 chars) 54 => array(5 items) id => 'pigmentbasis' (12 chars) name => 'Pigmentbasis' (12 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-210' (6 chars) 55 => array(5 items) id => 'prüfzeugnisse' (14 chars) name => 'Prüfzeugnisse' (14 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-215' (6 chars) 56 => array(5 items) id => 'phWert' (6 chars) name => 'pH-Wert' (7 chars) value => '8,5 ± 1,0' (11 chars) type => '&[java.lang.String]' (19 chars) position => '04-216' (6 chars) 57 => array(5 items) id => 'rissüberbrückungsfähigkeit' (29 chars) name => 'Rissüberbrückungsfähigkeit' (29 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-217' (6 chars) 58 => array(5 items) id => 'rohdichte14' (11 chars) name => 'Rohdichte' (9 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-220' (6 chars) 59 => array(5 items) id => 'schüttdichte' (13 chars) name => 'Schüttdichte' (13 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-225' (6 chars) 60 => array(5 items) id => 'sdWertZusammengesetz' (20 chars) name => 'sd-Wert - zusammengesetz' (24 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-230' (6 chars) 61 => array(5 items) id => 'sorptionsfeuchte' (16 chars) name => 'Sorptionsfeuchte' (16 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-231' (6 chars) 62 => array(5 items) id => 'spritzunterbrechung' (19 chars) name => 'Spritzunterbrechung' (19 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-235' (6 chars) 63 => array(5 items) id => 'standzeitBisZurGewebespachtelung' (32 chars) name => 'Standzeit bis zur Gewebespachtelung' (35 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-240' (6 chars) 64 => array(5 items) id => 'trockenrohdichte' (16 chars) name => 'Trockenrohdichte' (16 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-245' (6 chars) 65 => array(5 items) id => 'trocknungszeit' (14 chars) name => 'Trocknungszeit' (14 chars) value => 'Die Trockenzeiten liegen bei Normalbedingungen (+ 20°C / 65 % Luftfeuchte)
            bei ca. 12 Stunden, tiefere Temperaturen und höhere Luftfeuchte verlängern
             diese Zeit.
' (164 chars) type => '&[java.lang.String]' (19 chars) position => '04-255' (6 chars)
66 => array(5 items) id => 'verarbeitungstemperaturLuft' (27 chars) name => 'Verarbeitungstemperatur (Luft)' (30 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-260' (6 chars) 67 => array(5 items) id => 'verarbeitungstemperaturUntergrund' (33 chars) name => 'Verarbeitungstemperatur (Untergrund)' (36 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-261' (6 chars) 68 => array(5 items) id => 'verarbeitungszeit' (17 chars) name => 'Verarbeitungszeit' (17 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-265' (6 chars) 69 => array(5 items) id => 'verdünnung' (11 chars) name => 'Verdünnung' (11 chars) value => 'wasserverdünnbar <br/> max. 10 % bei Grundanstrich, <br/> max. 5 % bei De
            ckanstrich
' (87 chars) type => '&[java.lang.String]' (19 chars) position => '04-275' (6 chars)
70 => array(5 items) id => 'verzögertJeNachWitterung' (25 chars) name => 'Verzögert je nach Witterung' (28 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-280' (6 chars) 71 => array(5 items) id => 'vocGehalt' (9 chars) name => 'VOC-Gehalt' (10 chars) value => '1,9 g/l nach DIN EN ISO 11890-2 <br/> zulässiger Grenzwert 40,0 g/l <br/> l
            ösemittelfrei, umweltfreundlich geruchsarm
' (120 chars) type => '&[java.lang.String]' (19 chars) position => '04-281' (6 chars)
72 => array(5 items) id => 'w24Wert' (7 chars) name => 'W 24 Wert' (9 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-285' (6 chars) 73 => array(5 items) id => 'wärmeleitfähigkeit' (20 chars) name => 'Wärmeleitfähigkeit' (20 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-290' (6 chars) 74 => array(5 items) id => 'wasserabweisend' (15 chars) name => 'Wasserabweisend' (15 chars) value => NULL type => '[java.lang.Boolean]' (19 chars) position => '04-291' (6 chars) 75 => array(5 items) id => 'wasserBindemittelWert' (21 chars) name => 'Wasser/Bindemittel-Wert' (23 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-295' (6 chars) 76 => array(5 items) id => 'wasseraufnahme8' (15 chars) name => 'Wasseraufnahme' (14 chars) value => NULL type => 'list' (4 chars) position => '04-300' (6 chars) 77 => array(5 items) id => 'wasseraufnahmekoeffizient' (25 chars) name => 'Wasseraufnahmekoeffizient' (25 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-301' (6 chars) 78 => array(5 items) id => 'wasserbedarf' (12 chars) name => 'Wasserbedarf' (12 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-310' (6 chars) 79 => array(5 items) id => 'wasserdampfdiffusionswiderstandszahl' (36 chars) name => 'Wasserdampfdiffusionswiderstandszahl' (36 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-311' (6 chars) 80 => array(5 items) id => 'wasserdampfdurchlässigkeit' (27 chars) name => 'Wasserdampfdurchlässigkeit' (27 chars) value => ' V1 hoch nach DIN EN 1062-1 <br/> SD = 0,05 m nach DIN EN ISO 7783-2 ' (69 chars) type => '&[java.lang.String]' (19 chars) position => '04-315' (6 chars) 81 => array(5 items) id => 'weissgrad' (9 chars) name => 'Weissgrad' (9 chars) value => ' nach CIE = &gt; 95%' (20 chars) type => '&[java.lang.String]' (19 chars) position => '04-318' (6 chars) 82 => array(5 items) id => 'winterrezeptur' (14 chars) name => 'Winterrezeptur' (14 chars) value => FALSE type => '[java.lang.Boolean]' (19 chars) position => '04-319' (6 chars) 83 => array(5 items) id => 'µWert' (6 chars) name => 'µ - Wert' (9 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-433' (6 chars) 84 => array(5 items) id => 'zuBeachten' (10 chars) name => 'zu beachten' (11 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-500' (6 chars) 85 => array(5 items) id => 'test' (4 chars) name => 'Test' (4 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '04-552' (6 chars)
web_datenblatt => array(1 item) 0 => array(5 items) id => 'dateinameDatenblattOnline' (25 chars) name => 'Dateiname - Datenblatt online' (29 chars) value => 'TM-DE-SLSOLARFARBE.pdf' (22 chars) type => '&[java.lang.String]' (19 chars) position => '0' (1 chars) web_leistungserklaerung_fm => array(1 item) 0 => array(5 items) id => 'dateinameLeistungserklärungFm' (30 chars) name => 'Dateiname - Leistungserklärung FM' (34 chars) value => 'LEN-DE-_fm.pdf' (14 chars) type => '&[java.lang.String]' (19 chars) position => '0' (1 chars) web_leistungserklaerung_mbw => array(1 item) 0 => array(5 items) id => 'dateinameLeistungserklärungMbw' (31 chars) name => 'Dateiname - Leistungserklärung MBW' (35 chars) value => 'LEN-DE-_mbw.pdf' (15 chars) type => '&[java.lang.String]' (19 chars) position => '0' (1 chars) web_leistungserklaerung_bk => array(1 item) 0 => array(5 items) id => 'dateinameLeistungserklärungBk' (30 chars) name => ' Dateiname - Leistungserklärung BK' (35 chars) value => 'LEN-DE-_bk.pdf' (14 chars) type => '&[java.lang.String]' (19 chars) position => '0' (1 chars) web_leistungserklaerung_sgw => array(1 item) 0 => array(5 items) id => 'dateinameLeistungserklärungSgw' (31 chars) name => ' Dateiname - Leistungserklärung SGW' (36 chars) value => 'LEN-DE-_sgw.pdf' (15 chars) type => '&[java.lang.String]' (19 chars) position => '0' (1 chars) web_sicherheitsdatenblatt => array(1 item) 0 => array(5 items) id => 'dateinameSicherheitsdatenblatt' (30 chars) name => 'Dateiname - Sicherheitsdatenblatt' (33 chars) value => 'SDB-DE-SLSOLARFARBE.pdf' (23 chars) type => '&[java.lang.String]' (19 chars) position => '0' (1 chars) web_nachhaltigkeit_datenblatt => array(1 item) 0 => array(5 items) id => 'nachhaltigkeitsdatenblatt' (25 chars) name => 'Nachhaltigkeitsdatenblatt' (25 chars) value => NULL type => '&[de.myview.objectmodel.util.Hyperlink]' (39 chars) position => '1' (1 chars) web_nachhaltigkeit_epd => array(1 item) 0 => array(5 items) id => 'epd' (3 chars) name => 'EPD' (3 chars) value => NULL type => '&[de.myview.objectmodel.util.Hyperlink]' (39 chars) position => '2' (1 chars) web_produktklasse => array(1 item) 0 => array(5 items) id => 'artikelgruppeCode' (17 chars) name => 'Artikelgruppe - Code' (20 chars) value => 'PU' (2 chars) type => '&[java.lang.String]' (19 chars) position => '02-026' (6 chars) web_artikeleinheit => array(1 item) 0 => array(5 items) id => 'artikeleinheitBezeichnung' (25 chars) name => 'Artikeleinheit (Bezeichnung)' (28 chars) value => array(1 item) 0 => 'Eimer' (5 chars) type => 'list' (4 chars) position => '01-021' (6 chars) web_inhaltsmenge => array(1 item) 0 => array(5 items) id => 'inhaltsmengeAnzahlInhaltseinheitenProArtikeleinheit' (51 chars) name => 'Inhaltsmenge (Anzahl Inhaltseinheiten pro Artikeleinheit)' (57 chars) value => '15' (2 chars) type => '[de.myview.util.Dimension]' (26 chars) position => '01-030' (6 chars) web_inhaltseinheit => array(1 item) 0 => array(5 items) id => 'inhaltseinheit' (14 chars) name => 'Inhaltseinheit' (14 chars) value => array(1 item) 0 => 'LTR' (3 chars) type => 'list' (4 chars) position => '01-031' (6 chars) web_empf_schichtdicke => array(1 item) 0 => array(5 items) id => 'empfohleneSchichtdicke35' (24 chars) name => 'Empfohlene Schichtdicke' (23 chars) value => '' (0 chars) type => '&[java.lang.String]' (19 chars) position => '04-090' (6 chars) web_logistik => array(1 item) 0 => array(5 items) id => 'logistik' (8 chars) name => 'Logistik' (8 chars) value => 'In Eimern á 5 / 15 Liter' (25 chars) type => '&[java.lang.String]' (19 chars) position => '03-999' (6 chars) web_produktfilter => array(6 items) 0 => array(5 items) id => 'produktfilter' (13 chars) name => 'Produktfilter' (13 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '0' (1 chars) 1 => array(5 items) id => 'produktfilterKategorieMindmap' (29 chars) name => 'Produktfilter - Kategorie MindMap' (33 chars) value => NULL type => 'list' (4 chars) position => '0' (1 chars) 2 => array(5 items) id => 'produktfilterHilsmerkmalEbene2' (30 chars) name => 'Produktfilter - Hilsmerkmal - Ebene 2' (37 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '005' (3 chars) 3 => array(5 items) id => 'produktfilterHilsmerkmalEbene3' (30 chars) name => 'Produktfilter - Hilsmerkmal - Ebene 3' (37 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '010' (3 chars) 4 => array(5 items) id => 'produktfilterHilsmerkmalEbene4' (30 chars) name => 'Produktfilter - Hilsmerkmal - Ebene 4' (37 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '015' (3 chars) 5 => array(5 items) id => 'produktfilterHilsmerkmalEbene5' (30 chars) name => 'Produktfilter - Hilsmerkmal - Ebene 5' (37 chars) value => NULL type => '&[java.lang.String]' (19 chars) position => '020' (3 chars)
MAM_Pixelboxx:pboxx-pixelboxx-13526

Produktkurzbeschreibung

maxit Solarfarbe ist eine lösungsmittelfreie Fassadenfarbe auf Silikonharzbasis mit mineralischer Grundstruktur und einem hohen Anteil an microfeinen Hohlglaskugeln.

Der hohe Anteil an Microhohlglaskugeln bewirkt einen Isoliereffekt der Farbe, der zu einer deutlichen Verlangsamung der Wärmedurchleitung führt. Damit wird der Taupunkt an der Fassade positiv beeinflusst, die Wand bleibt länger trocken.

maxit Solarfarbe ist wasserabweisend eingestellt (niedrige kapillare Wasseraufnahme W3), hat aber durch ihre spezielle Rezeptur eine microporöse hydrophile Oberfläche, die anhaftende Feuchtigkeit sehr schnell von der Oberfläche ableitet.

Durch die Kombination der beiden beschriebenen physikalischen Effekte wird mit maxit Solarfarbe ein lang anhaltender Schutz der Fassade gegen Algen- und Pilzbefall erreicht, der sich im Laufe der Jahre, im Gegensatz zu herkömmlicher fungizider algizider Ausrüstung, auch nicht abbaut.

Diese ausgezeichneten bauphysikalischen Eigenschaften machen maxit Solarfarbe zu einem äußerst leistungsfähigen Wetterschutz an der Fassade.

Ein zweimaliger Anstrich mit maxit Solarfarbe ist unbedingt erforderlich um die beschriebenen Produktvorteile zu erreichen. Weiß oder farbig nach maxit kreativ Farbtonkarte.



maxit Solarfarbe ist eine lösungsmittelfreie Fassadenfarbe mit mineralischer Grundstruktur, einsetzbar auf maxit Solarputz oder maxit Solarfassadenspachtel bzw. maxit silco A 9030, maxit spectra A 9040, maxit sil A 9020, allen Putzarten und mineralischen Untergründen.
  • langlebiger, ökologischer Schutz der Bausubstanz
  • optimaler Schutz gegen Algen
  • langanhaltende Farbbrillanz
  • wärmeregulierend
  • spannungsarme, flexible Fassadenbeschichtung
  • feuchteregulierend durch microporöse Struktur
  • geringe Verschmutzungsneigung
Der Untergrund muss trocken, fest, frei von Staub und losen Teilen bzw. Trennmitteln (z.B. Schalöl) sein. Die Objekt- und Umgebungstemperatur darf nicht unter
+ 5°C und nicht über + 30°C liegen. Die Trockenzeiten liegen bei Normalbedingungen (+ 20°C / 65 % Luftfeuchte) bei ca. 12 Stunden, tiefere Temperaturen und höhere Luftfeuchte verlängern diese Zeit.
Je nach Untergrund ist ein Voranstrich mit maxit prim 1070 Tiefgrund, maxit Solarfarbgrund oder maxit prim 1110 Hydrogrund erforderlich.
Schmutzempfindliche Bauteile abdecken bzw. wasserfest abkleben.
maxit Solarfarbe ist gebrauchsfertig. Eine Verdünnung kann bei Grund- und Zwischenanstrichen ca. 5 - 10 %, bei Schlussanstrichen bis ca. 2 - 5 % mit sauberem Wasser erfolgen. Vor der Verarbeitung ist die Solarfarbe gut aufzurühren. Nicht bei direkter Sonneneinstrahlung, Regen oder hoher Luftfeuchtigkeit verarbeiten. Dieses Produkt stets sicher verwenden. Produktinformationen vor Gebrauch beachten.
Je nach Art und Saugverhalten des Untergrundes ca.
0,2 - 0,4 l/m² bei einmaligen Anstrich. Achtung: Raue Oberflächen können den Verbrauch erhöhen. Exakte Verbrauchsmengen sind durch Anlegen von Probeflächen zu ermitteln.
Nachbehandlung:
Frische Farbe vor zu schneller Austrocknung durch Sonneneinstrahlung und/ oder Wind schützen.

Beschichtung:
Eine 100%ige Farbtongleichheit zwischen Oberfläche und Farbe oder auch den Farbtonfächern kann aufgrund der unterschiedlichen Pigmentierung nicht gewährleistet werden. Farbtonunterschiede sind auch bei gleichem Farbton nicht immer auszuschließen. maxit Solarfarbe kann mit Silikat-Dispersion-, Siliconharz- und Dispersionsfarben überarbeitet werden.

Weiterverarbeitung:
Bei intensiven Farbtönen und ungleichen Farben z.B. weißer Putz, farbigen Anstrich und zum Erreichen eines guten Witterungsschutzes, ist generell ein zweimaliger Anstrich auszuführen. Die Standzeiten des maxit Oberputzes bis zum Farbauftrag sind dem Hinweisblatt „Minimale Standzeiten vor dem Farbauftrag“ unter
www.maxit.de zu entnehmen.
In Zweifelsfällen bezüglich Verarbeitung oder Objektbesonderheiten Beratung anfordern. Keine Fremdstoffe beimischen.
Haut und Augen schützen, bei Berührung gründlich mit Wasser spülen, bei Augenkontakt unverzüglich Arzt aufsuchen.
Sicherheitsdatenblatt beachten (aktuelles Sicherheitsdatenblatt unter www.maxit.de).
In abgebundenem Zustand physiologisch und ökologisch unbedenklich.
Zu beachten: Prüfung des Materials vor Verarbeitung, ob es dem bestellten Farbton entspricht. Es kann zu geringen Farbtonabweichungen vorhergegangener Lieferungen kommen. Auf zusammenhängenden Flächen nur Material einer Charge verwenden. Vor der Verarbeitung sind unterschiedliche Chargen zu mischen. Abzeichnungen von Ausbesserungen in der Fläche hängen von vielen Faktoren ab und sind daher unvermeidbar (BFS-Merkblatt 25).

Bei dichten, kühlen Untergründen oder bei witterungsbedingter Trocknungsverzögerung, können durch Feuchtebelastung (Regen, Tau, Nebel) Hilfsstoffe an der Oberfläche der Beschichtung gelblich/transparente, leicht glänzende und klebrige Ablaufspuren entstehen. Diese Hilfsstoffe sind wasserlöslich und werden  mit ausreichend Wasser, z.B. nach mehrmaligen stärkeren Regenfällen selbstständig entfernt. Die Qualität der getrockneten Beschichtung wird dadurch nicht nachteilig beeinflusst. Bei Ausführung der Beschichtung unter geeigneten klimatischen Bedingungen treten diese Ablaufspuren nicht auf.
Der Einsatz bewährter und fortlaufend kontrollierter Rohstoffe garantiert eine gleichbleibend gute Qualität. Modernste Fertigungsanlagen sorgen für konstante Produkteigenschaften. In den werkseigenen Baustofflaboren erfolgt eine konstante Qualitätsüberwachung der Produkte.
Vor Frost schützen. In original verschlossenen Gebinden mindestens 12 Monate lagerfähig.
Eimer sind komplett zu entleeren, Entsorgung gemäß den behördlichen Vorschriften.








Airless Spritzdaten:
Verdünnung  
5 % mit Wasser 
Spritzdruck ≤ 80 bar* / **
Düsengröße 0,023
Maschenweite Sieb  
60 mesh
Schlauchlänge mind. 15 m x 1/4"


bar* Druckeinstellungen sind den Gegebenheiten anzupassen, sie sind von Lieferkonsistenz und Umgebungstemperatur stark beeinflusst.
** erhöhter Druck führt zu Materialschäden


Sicherheitshinweis:
Bei allen Spritzapplikationen sind die Verarbeitungsrichtlinien der Produkte sowie der verwendeten Spritzgeräte zu beachten. Bei Verarbeitung aller Materialien ist sicherzustellen, dass die Baustelle entsprechend gut belüftet wird, ent-sprechende Arbeitsschutzmasken zu tragen sind und die Geräte entsprechend gesichert sind (Ex-Schutz).
Die genannten Werte und die zugesicherten Eigenschaften sind das Ergebnis intensiver Entwicklungsarbeit und umfangreicher praktischer Erfahrungen. Sie basieren auf den Ergebnissen sowohl der Eigen- wie auch der Fremdüberwachung. Unsere Empfehlungen zur Anwendung in Wort und Schrift sollen Hilfestellungen bei der Auswahl unserer Produkte geben, sie bekunden jedoch kein vertragliches Rechtsverhältnis. Wir gehen davon aus, dass der Kunde als Fachbetrieb in eigener Verantwortung entsprechend der gültigen Vorschriften und den anerkannten Regeln der Technik seine Arbeit ausführt. Die fachgerechte und damit erfolgreiche Anwendung unserer Erzeugnisse unterliegt nicht unserer Kontrolle. Hinweise, wie z.B. die Aufzählung geeigneter Putzuntergründe, haben nicht den Charakter einer zugesicherten Eigenschaft und entbinden den Kunden nicht von seiner Prüfungspflicht. Des Weiteren bitte auch die gültigen technischen Merkblätter des Bundesausschusses für Farbe und Sachwertschutz (=BFS), 60327 Frankfurt, berücksichtigen. Mit dem Erscheinen dieses Merkblattes verlieren alle früheren Merkblätter ihre Gültigkeit.
In Eimern á 5 / 15 Liter
Edelputz / Farbe
maxit Solarfarbe
Anwendung aussen Ja
Deckkraftklasse Klasse 2 (DIN ISO 6404-3)
Dichte 1,0 ± 0,1 g/cm³
Körnung max. 100 µm
Edelputz / Farbe
maxit Solarfarbe
pH-Wert 8,5 ± 1,0
Trocknungszeit Die Trockenzeiten liegen bei Normalbedingungen (+ 20°C / 65 % Luftfeuchte) bei ca. 12 Stunden, tiefere Temperaturen und höhere Luftfeuchte verlängern diese Zeit.
Verdünnung wasserverdünnbar
max. 10 % bei Grundanstrich,
max. 5 % bei Deckanstrich
VOC-Gehalt 1,9 g/l nach DIN EN ISO 11890-2
zulässiger Grenzwert 40,0 g/l
lösemittelfrei, umweltfreundlich geruchsarm
Wasserdampfdurchlässigkeit V1 hoch nach DIN EN 1062-1
SD = 0,05 m nach DIN EN ISO 7783-2
Weissgrad nach CIE = > 95%